Fire rated Speedpanel walls – horizontally oriented panels
We have what you need.
Ensure you successfully design and install Speedpanel into your project to make it a success.
Fire rated Speedpanel walls – horizontally oriented panels
INCREASED FRL OF VERTICAL SPEEDPANEL WALLS
Increasing FRL of 78 mm, 64 mm and 51 mm thick dual Speedpanel wall systems – in accordance with AS 1530.4:2014
SPEEDPANEL VERTICAL WALLS
Fire resistance of 51mm and 64mm Speedpanel walls up to 5.0m in height and 78mm Speedpanel walls up to 6.0m in height. Includes curved, segmented and out of plumb wall systems.
HORIZONTAL & VERTICAL WALLS
Assessment of non-load bearing horizontal and vertical orientated Speedpanel wall with variations to connection details.
SPEEDPANEL JUNCTION DETAIL
Fire resistance of Speedpanel Junction Detail.
HORIZONTAL AND VERTICAL WALLS WITH INCREASED HEIGHT & WIDTH VARIATIONS
Assessment of a non-load bearing horizontal and vertical orientated Speedpanel wall with increased height and width variations.
FYREHATCH WALL ACCESS HATCHES IN SPEEDPANEL WALLS
Fire resistance of Fyregard, Fyrehatch wall access hatches in Speedpanel walls.
MODIFIED SPEEDPANEL WALL SYSTEM
Likely fire performance of your modified Speedpanel wall system.
FRL -/180/180
FRL -/180/120
WALL SYSTEMS INCORPORATING BLENDAIR MFD SERIES, SBFP SERIES, SHD SERIES AND SSD SERIES DAMPERS
The fire resistance performance of 78mm thick Speedpanel wall systems incorporating Blendair MFD Series, SBFP Series, SHD Series and SSD Series dampers when tested in accordance with AS1530.4-1997 section 7.
78MM VERTICALLY ORIENTATED WALL SYSTEM WITH MOVEMENT POTENTIAL OF JOINT PRIOR TO FIRE EVENT
An assessment of the fire resistance performance of 78mm thick vertically orientated Speedpanel wall system with movement potential of joint prior to fire event if tested in accordance with AS1530.4-2014
SPEEDPANEL CEILINGS AND BULKHEADS
Speedpanel ceiling and supporting wall systems in accordance with AS1530.4:2014.
SPEEDPANEL CONNECTION TO FR PLASTERBOARD
Up to FRL -/120/120 | 78mm, 64mm and 51mm
Fire resistance performance of interfaces between Speedpanel and FR plasterboard systems.
SPEEDPANEL WITH MASS TIMBER
78 mm, 64 mm and 51 mm thick Speedpanel wall systems with mass timber construction.
WALL SYSTEMS WITH FACE LOADINGS
Fire resistance performance of Speedpanel wall systems with face loadings.
CONTINUOUS HEIGHT, HORIZONTAL WALL INTERFACED WITH HORIZONTAL WALL
Assessment of a non-load bearing continuous height, horizontal orientated Speedpanel wall interfaced with a Horizontal Speedpanel wall.
WALLS INCORPORATING WINDOW OPENINGS
Fire resistance of vertical Speedpanel walls incorporating window openings.
SPEEDPANEL WALL SYSTEM INSTALLED IN A SCISSOR STAIR CONFIGURATION
FRL -/120/120 | 78mm | Stairs
Performance of 78mm Speedpanel wall system installed in a scissor stair configuration.
SPEEDPANEL AND STRUCTURAL STEEL INTEGRATED WALL SYSTEMS
An assessment of the fire resistance performance of Speedpanel and structural steel integrated wall systems.
SPEEDPANEL PARTY WALL SYSTEMS
Up to FRL -/120/120 | 51, 78mm | Party Walls
Performance of 51mm and 78mm Speedpanel party wall systems installed vertically, up to 14.0m in a townhouse application.
NON-LOAD BEARING HORIZONTAL AND VERTICAL ORIENTATED WALL WITH VARIATIONS TO CONNECTION DETAILS
FRL -/120/120 | 78mm | Shafts
Performance of 78mm non-load bearing horizontal and vertical orientated wall with variations to connection details.
SPEEDPANEL JUNCTION DETAIL
FRL -/120/120 | 78mm | Shafts
Performance of 78mm Speedpanel junction detail.
78MM NON-LOAD BEARING CONTINUOUS HEIGHT
FRL -/120/120 | 78mm | Shafts
Performance of 78mm non-load bearing continuous height, horizontal orientated wall interfaced with a horizontal wall.
External Walls (NCC2016-NCC2022)
Speedpanel external wall systems have been tested against NCC Verification Methods FV1.1 and V2.2.1 (now F3V1 and H2V1) and appraised to meet the performance requirements FP1.4 and P2.2.2 (now F3P1 and H2P2) for weatherproofing. This may be used as a basis for a Performance Solution (as per NCC section F1.0 [now F3D1 and F3D5]). Contact Speedpanel for more information.
DETERMINATION OF FIRE HAZARD PROPERTIES (WALL & CEILING LININGS)
Short Form Certificate – The group number of the Speedpanel wall or ceiling lining and the smoke growth rate index when determined in accordance with AS 5637.1:2015 – Determination of fire hazard properties (all and ceiling linings)
NON-COMBUSTIBILITY CERTIFICATE
Non-Combustibility Certificate for Materials – AS 1530.1:1994 – Methods for fire tests on building materials, components and structures
LIPVC, HDPE AND COESTILEN® HDPE PIPE PENETRATIONS PROTECTED BY PROMASEAL® FCS AND FC RETROFIT COLLARS
The fire resistance performance of LIPVC, HDPE and Coestilen® HDPE pipe penetrations protected by PROMASEAL® FCS and FC retrofit collars in walls and floors if tested in accordance with AS1530.4-2005 and assessed in accordance with AS4072.1-2005
WALL SYSTEMS INCORPORATING BLENDAIR MFD SERIES, SBFP SERIES, SHD SERIES AND SSD SERIES DAMPERS
The fire resistance performance of 78mm thick Speedpanel wall systems incorporating Blendair MFD Series, SBFP Series, SHD Series and SSD Series dampers when tested in accordance with AS1530.4-1997 section 7.
FIRE RESISTANCE PERFORMANCE ALL SYSTEM INCORPORATING PROMASEAL ® FYRESTRIP
The likely fire resistance performance of various expansion joints in Speedpanel wall system incorporating PROMASEAL ® FyreStrip if tested in accordance with AS1530.4-2014 and AS4072.1:2005